Three Phase Detector Rotary Tester Non-Contact Phase Sequence Tester
SKU: MMT211532/MMT211532-1
$79.00 - $89.00Kainų intervalas: Nuo $79.00 iki $89.00
- 01Added a function “Motor Rotation detection”Non-contact rotating magnetic field Indication
- DYXZ-01 can dectect rotation of single phase and three phase motor. But can not detect motors controlled by frequercy converter
- Phase Detection
- Live Voltage Detection
- Phase missing Detection
Greitas pristatymas per 48 valandas
2 metų garantija, nemokamos atsarginės dalys
DY29 This is an automotive tool for the OBDII Diagnostic Link Connector that provides easy access to the OBDII connector for convenient and safe monitoring of protocol, power and ground signals. Once an unconfirmed signal is detected, it can also be connected to a multimeter or oscilloscope for further testing.
Automobilių diagnostikos protokolo testeris DY29 Funkcijos
- DYXZ-02 non-contact phase rotation tester designs for quick , easy and accurate detection of three phase sequence in motor installation and repair . The non-connection to insulated conductor avoids uncertain and difficult connections to bare high voltage wires
- This is a phase detector, designed to perform phase sequence checks and live line checks of a 3-phase circuit using a static induction voltage clip.
- The static induction voltage clips are used to be able to clip on a cladded wire.It is small with a CAT 600V safety rating.
- Red LED lamps are used to make the indication visible in dimly lit areas.The direction of phase sequence can be checked easily using the LED lamps, which blink in order.
- MRCARTOOL suteikia 48 mėnesių garantiją ir 7×24 valandų draugišką klientų aptarnavimą, kad užtikrintų jūsų apsipirkimo patirtį. Jei turite klausimų apie Evap Leak Tester, susisiekite su mumis tiesiogiai.
Test operation
Connection:
1.Connect the three non-contact alligator clips to the three
2.phase power cables.
(2)The symbol or each clip should be placed at the center of each cables.
(3)Press “ON”,lightA,B,C flashes once to power on the tester.
(4)In case the A,B,C are lit up , R is on if positive CW is detected.
1.If in negative CCW, L is on.
2.If one or more of light A,B,C does not light up , it means the relevant phase is open. In this case, R or L does not represent the indication.
(5)Press “OFF” to shut down the tester after use
CAUTION ! HIGH VOLTAGE !
(1)Connect any of the alligator clips to the conductor. If the conductor is powered on (Voltage within 70~600V AC),the relevant light A,B,C should light up.This can quickly determine if the conductor is powered on.
(2)Clips and lights reference table
|
Clips |
Lights |
|
A (yellow ,left) |
Light A |
|
B(green ,middle) |
Light B |
|
C(red , right) |
Light C |


Pakuočių sąrašas
| Svoris | 1 kg |
|---|---|
| Laivas iš | Kinija, Vokietija, Jungtinė Karalystė, Jungtinės Amerikos Valstijos |
| Modelis |
Pristatymas
KLAUSIMAI IR ATSAKYMAI
Three Phase Detector Rotary Tester Non-Contact Phase Sequence Tester